风韵丰满熟妇啪啪区老熟熟女_亚洲AⅤ永久无码毛片牛牛影视_中文字幕无码日韩欧免费软件_中文字幕久精品免费视频

歡迎來到北京豫維科技有限公司網站!

熱門關鍵詞:蘇瑪罐,原子吸收分光光度計,環境監測產品,液相色譜,色譜柱。

產品中心您現在的位置:首頁 > 產品展示 > 液相色譜柱 > 離子色譜柱 > Dionex IonPac AS20 陰離子交換柱 063148

Dionex IonPac AS20 陰離子交換柱 063148

更新時間:2019-11-20

簡要描述:

Dionex IonPac AS20 陰離子交換柱 063148
飲用水中高氯酸鹽的簡化,地表水和地下水的微量分析

  免費咨詢:010-61755520

  發郵件給我們:yuweichina86@163.com

Dionex IonPac AS20 陰離子交換柱 063148

飲用水中高氯酸鹽的簡化,地表水和地下水的微量分析,矩陣使用Thermo Scientific? Dionex? IonPac? AS20毛細管,分析保護柱。本專欄的容量和選擇性確保高氯酸鹽可以量化的低μg/L采用抑制電導檢測的濃度,即使在濃度很高的氯化物,碳酸鹽和硫酸鹽的存在。本欄是美國環保局規定的314.1用于樣品預濃縮后飲用水中痕量高氯酸的測定(驗證性方法)。

 

Dionex IonPac AS20 陰離子交換柱 063148

訂貨信息:

Dionex IonPac AS20 陰離子交換柱

分析柱
IonPac AS20 Analytical Column (2 x 250 mm)063065
IonPac AS20 Analytical Column (4 x 250 mm)063148
IonPac AS20 Capillary Column (0.4 x 250 mm)075399
保護柱
IonPac AG20 Guard Column (2 x 50 mm)063066
IonPac AG20 Guard Column (4 x 50 mm)063154
IonPac AG20 Capillary Guard Column (0.4 x 50 mm)075400

 

 

For Determination of Trace Perchlorate Using Suppressed Conductivity Detection

The IonPac? AS20 hydroxide-selective anion-exchange column is specifically designed for determination of trace concentrations of perchlorate in drinking water, surface water, and groundwater matrices. The capacity and selectivity of the AS20 ensures that perchlorate can be quantified at low μg/L concentrations using suppressed conductivity detection, even in the presence of very high concentrations of chloride, carbonate, and sulfate. The new IonPac AS20 Capillary Column is packed with the same material as the equivalent standard bore version (providing the same performance as a 4 mm column) but requires only 1/100th the eluent flow rate. The capillary format provides the advantage of significantly reduced eluent consumption, which helps reduce operating costs.

  • Recommended for US EPA Method 314.1 (Confirmatory Method)

  • High capacity: 310 μeq per column. (4 × 250 mm)

  • Use the Cryptand C1 Concentrator Column for sample preconcentration with the analytical column

  • Simplified Reagent-Free IC operation provided by the Eluent Generator

  • ASRS 300 or ACES 300 provides RFIC operation with low background and enhanced analyte sensitivity

  • Column selectivity is optimized for 30 °C operating temperature

  • Compatible with organic solvents

The IonPac AS20 is the specified column in US EPA Method 314.1 (Confirmatory Method). The Cryptand C1 Concentrator Column is the specified concentrator column for sample preconcentration in that method.

Use the IonPac AS20 column with an RFIC? system for optimum detection limits. Use the Anion Self-Regenerating Suppressor (ASRS? 300) or the Anion Capillary Electrolytic Suppressor (ACES 300) with the AS20 column for eluent suppression.

 

IonPac AS20 Anion-Exchange Column   Specifications
Maximum Operating Pressure:4000 psi (standard and microbore) 5000 psi (capillary)
Mobile Phase Compatibility:pH 0–14; 0–100% HPLC solvents
Ion Exchange Group:Functional Group: Alkanol quaternary ammonium ion
Column Construction:PEEK with 10–32 threaded ferrule style end fittings.
All components are nonmetallic.
Functional Group Characteristics:Ultralow Hydrophobicity
Dimensions:
IonPac AS20 Capillary Column:
0.4 ×250 mm 
IonPac AG20 Capillary Guard Column: 
0.4 × 50 mm 
IonPac AS20 Analytical Column:
2 × 250 mm
IonPac AG20 Guard Column:
2 × 50 mm
IonPac AS20 Analytical Column:
4 × 250 mm
IonPac AG20 Guard Column:
4 × 50 mm

 

Capacity:

3.1 μeq (0.4 × 250 mm capillary column)
77.5 μeq (2 × 250 mm analytical column)
310 μeq (4 × 250 mm analytical column)
0.06 μeq*(0.4 × 50 mm capillary guard column)
1.5 μeq* (2 × 50 mm guard column)
6 μeq* (4 × 50 mm guard column)
*Guards are packed with a low-capacity microporous resin.

Substrate Characteristics:Bead Diameter and Pore Size:
7.5 μm (2 × 250, 4 × 250 and 0.4 × 250 mm);
super macroporous resin (2000 ?)
11 μm (2 × 50, 4 × 50 and 0.4 × 50 mm);
microporous resin (<1 ?)
Crosslinking (%DVB): 55%

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7